3.4.2.

Connecting the Power Cables

Access the power terminal connections on the Tuba servo drive by removing the front safety
cover located at the bottom of the front panel of the unit, as shown below:

Figure 8: Removable Bottom Panel

After removing the safety cover, the power terminal connections are visible, as follows:

Figure 9: Tuba Power Connectors

The main power connector, which is located at the bottom of the Tuba, has the following pins:

Pin

Function

Cable

Pin Positions

B1

DC Link (+)

DC Link

B2

DC Link (-)

DC Link

AC3

Phase 3

Power

AC2 Phase 2

Power

AC1 Phase 1

Power

PE

Protective earth

Power

AC Motor Cable DC Motor Cable

PE

Protective earth

Motor

Motor

M3

Motor phase

Motor

N/C*

M2

Motor phase

Motor

Motor

M1

Motor phase

Motor

Motor*

Note:

When connecting several motors, all must be wired in an identical manner.

*On prototype versions of the Tuba, M3 was connected to the Motor and M1 was not.

Table 2: Connector for Main Power and Motor Cables