I/os, Digital input interfaces (on the general i/o port) – ElmoMC AC Input Digital Servo Drives-Tuba User Manual

Page 73

Advertising
background image

Tuba Installation Guide

Technical Specifications

MAN-TUBIG (Ver. 1.502)

www.elmomc.com

73

4.10. I/Os

The Tuba has:

10 Digital Inputs

6 Digital Outputs

2 Analog Inputs

4.10.1. Digital Input Interfaces (on the GENERAL I/O port)

Feature

Details

Connector Location

Type of input

Optically isolated

Single ended

PLC level

Input current

=

2500

5

.

6 V

Vin

Iin

* Iin = 2.2 mA @ Vin = 12 V

Input current
for high speed
inputs 5 & 6

=

1250

5

.

6 V

Vin

Iin

* Iin = 4.4 mA @ Vin = 12 V

High-level input
voltage

12 V < Vin < 30 V, 24 V typical

Low-level input
voltage

0 V < Vin < 6.5 V

Minimum pulse
width

> 4 x TS, where TS is sampling time

Execution time
(all inputs):
the time from
application of
voltage on input
until execution
is complete

If input is set to one of the built-in functions — Home, Inhibit, Hard Stop,
Soft Stop, Hard and Soft Stop, Forward Limit, Reverse Limit or Begin —
execution is immediate upon detection:

0 < T < 4 x TS

If input is set to General input, execution depends on program. Typical
execution time: ≅ 0.5 msec.

Input Return (i)

DIGINPUT

Rin = 2.5K

Vz = 5.1 V

Digital Input Schematic

DIGITAL INPUTS

Advertising