Resolver, Tachometer, Resolver 4.9.6. tachometer – ElmoMC AC Input Digital Servo Drives-Tuba User Manual

Page 71

Advertising
background image

Tuba Installation Guide

Technical Specifications

MAN-TUBIG (Ver. 1.502)

www.elmomc.com

71

4.9.5.

Resolver

Feature

Details

Resolver format

Sine/Cosine

Differential

Input resistance

Differential 2.49 kΩ

Resolution

Programmable: 10 to 15 bits

Maximum electrical frequency (RPS)

512 revolutions/sec

Resolver transfer ratio

0.5

Reference frequency

1/Ts (Ts = sample time in seconds)

Reference voltage

Supplied by the Tuba

Reference current

Up to ±50 mA

4.9.6.

Tachometer*

Feature

Details

Tachometer format

Differential

Maximum operating differential voltage
for TAC1+, TAC1-

±20 V

Maximum absolute differential input
voltage for TAC1+, TAC1-

±25 V

Maximum operating differential voltage
for TAC2+, TAC2-

±50 V

Maximum absolute differential input
voltage for TAC2+, TAC2-

±60 V

Input resistance for TAC1+, TAC1-

46 kΩ

Input resistance for TAC2+, TAC2-

100 kΩ

Resolution

14 bit

* Only one Tachometer port can be used at a time (either TAC1+/TAC1- or TAC2+/TAC2-).
TAC1+/TAC1- is used in applications with having a Tachometer of less than 20 V.
TAC2+/TAC2- is used in applications with having a Tachometer of between 20 V and 50 V.