Tuba Installation Guide

Installation

MAN-TUBIG (Ver. 1.502)

www.elmomc.com

29

3.4.3.

Connecting the Auxiliary Supply Cable (24 V)

Connect the auxiliary supply to the 24 VDC terminal block on the bottom of the Tuba.
Remember, you are working with DC power; so be sure to exercise caution.

Notes for 24 VDC auxiliary supply connections:

Use a 24 AWG twisted pair shielded cable. For best results the shield should have

aluminum foil covered by copper braid.

The 24 VDC auxiliary power supply must meet all safety standards and must be separated

from hazardous live voltages using reinforced or double insulation in accordance with
approved safety standards.

For safety reasons, connect the return of the 24 VDC source to the closest ground.

Connect the cable shield to the closest ground near the 24 VDC source.

Before applying power, first verify the polarity of the connection.

Pin Signal

Function

Pin Positions

[+] +24VDC

+24 VDC auxiliary supply

[-]

RET24VDC Return (common) of the

24 VDC auxiliary supply

Table 3: Auxiliary Power Supply

TUB0017A

TUBA

Figure 13: Auxiliary Supply (24v) Connection Diagram