4.5. Power Ratings

Feature

Units 12/230 15/230 20/230 12/460

15/460

20/460

Minimum supply voltage

VAC

60

140

Nominal supply voltage

VAC

1 x 115, 1 x 230, 3 x 230

3 x 400, 3 x 460

Maximum supply voltage

VAC

1 x 270 or 3 x 270

3 x 505

Maximum continuous power

output

W

3600

4500

6000

6800

8500

11300

Efficiency at rated power (at

nominal conditions)

%

> 93

Auxiliary supply voltage `

VDC

24 ± 15%

Auxiliary power supply

VA

20

Amplitude sinusoidal/DC

continuous current

A

12

15

20

12

15

20

Sinusoidal continuous RMS

current limit (Ic)

A

8.5

10.6

14.1

8.5

10.6

14.1

Peak current limit

A

2 x Ic

Built-in shunt (peak power)

kW

6

11

Weight

kg (lbs)

2.7 kg (5.9 lbs)

Dimensions

mm

(in)

247 x 190 x 92 (9.7" x 7.5" x 3.6")

Digital in/Digital out/Analog

in

10/6/2

Mounting method

Wall mount (“Bookshelf”) or DIN rail

4.6. Environmental Conditions

Feature

Details

Operating ambient temperature

according to IEC60068-2-2

0 °C to 40 °C (32 °F to 104 °F)

Storage temperature

-20 °C to +85 °C ( -4 °F to +185 °F)

Maximum non-condensing humidity

according to IEC60068-2-78

95%

Maximum Operating Altitude

2,000 m (6562 feet)

Mechanical Shock

according to IEC60068-2-27

15g / 11ms Half Sine

Vibration

according to IEC60068-2-6

5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G