Sensor3 CE Rack (ESR3) Installation Manual

Installing ESR3-36 and ESR3-48 Racks on the Floor

Step 1:

Determine where your rack will be installed using

Figure 1: Sensor3 rack

clearances on page 4

and use the appropriate diagram from Figure 3 to mark

your mounting holes.

Step 2:

Drill the holes and install your own M10 mounting hardware.

Step 3:

Position the rack in the desired location.

Step 4:

Adjust the leveling feet with an open ended 12mm spanner until the rack is level

and vertical.

Step 5:

Secure the rack to the floor using your mounting hardware.

Pedestal Mounting an ESR3-24 Rack

Step 1:

Use Figure 3 to mark the location of the ESR3-24 mounting holes. The ESR3-24

pedestal has the same floor mounting dimensions as the ESR3-24 rack.

.

Step 2:

Drill holes or mount floor hardware and position the pedestal on them.

Step 3:

Secure the pedestal base to the floor.

Step 4:

Position the rack on the pedestal and align the mounting holes.

Step 5:

Bolt the rack into place.

N o t e :

Sensor3 racks of the same size are the single exception to the 15cm left clearance

requirement. They can be installed side by side without problems.

N o t e :

Sensor3 installation racks are tall, narrow, and heavy. Use caution to keep racks

stable until the rack is secured to the floor or wall.

N o t e :

You must supply M10 mounting hardware. The pedestal has four mounting holes

into the floor and four securing the rack.