Finishing Installation

27

C h a p t e r 5

Finishing Installation

The steps in this chapter should only be performed by, or after receiving approval from, an

authorised ETC representative.

Check Backplane DIP Switches

The backplane of your rack features a set of eight DIP switches allowing configuration of

the rack type. The CEM3 reads these DIP switches to determine the rack type, phasing and

available modules. Compare the position of these DIP switches to the table below and, if

necessary, set them to the correct position using a jewellers screwdriver.

Use the following chart to determine your required DIP switch settings:

Energising the System

You need ETC approval to apply power to your dimming system. Wiring errors in

unauthorised installations may endanger operators or cause system damage and failure.

Contacting ETC

To obtain ETC approval or for referral to an authorised ETC representative, contact ETC

as shown in

Contacting ETC, page 2

.

DIP Switch Number

Rack Model

1

2

3

4

5

6

7

8

ESR3-12

On

On

ESR3-12N

On

On

On

ESR3-12AF

On

On

On

ESR3-12AFN

On

On

On

On

ESR3-24

On

On

ESR3-24N

On

On

On

ESR3-24AF

On

On

On

ESR3-24AFN

On

On

On

On

ESR3-36

On

On

ESR3-36N

On

On

On

ESR3-36AF

On

On

On

ESR3-36AFN

On

On

On

On

ESR3-48

On

ESR3-48N

On

On

ESR3-48AF

On

On

ESR3-48AFN

On

On

On

W A R N I N G :

Do not attempt to energise the system without proper approval. Energising

the system without ETC approval may result in serious injuries.

C A U T I O N :

Energising your system without ETC approval may result in equipment damage

that may void your warranty!