Single pole racks, Neutral disconnect racks – ETC Sensor3 CE (ESR3) Rack User Manual

Page 45

Advertising
background image

C

Emergency Modules

37

Step 5:

Terminate the neutral as described below dependant on your rack type.

Single Pole Racks

For racks which have neutral jumpers fitted, the neutral of the load fed by the emergency

module should be connected to the neutral terminal of an adjacent module.

Neutral Disconnect Racks

In racks without neutral jumpers (Neutral Disconnect racks) the neutral of the load should

not be connected to another load’s neutral terminal. This can cause unwanted tripping of

RCD modules. Instead, an auxiliary neutral terminal must be fitted to the neutral plate and

the loads should be connected to the terminal. If your rack was ordered with Emergency

Modules the auxiliary neutral terminal should be factory fitted. If you require an auxiliary

neutral terminal, please contact ETC as shown using the details in

Contacting ETC, page 2

.

C A U T I O N :

It is important to correctly identify the Constant Live, Dimmed Live and Neutral

wires, as incorrect termination can cause damage to the fixture and/or dimmer

rack.