Running ethernet to racks, Ethernet with a nefm, Ethernet with an external network – ETC Sensor3 CE (ESR3) Rack User Manual

Page 30

Advertising
background image

22

Sensor3 CE Rack (ESR3) Installation Manual

Running Ethernet to Racks

Sensor3 racks use Ethernet for communication with each other and sometimes for

communication with the lighting console. It is therefore important that all racks are linked

via Ethernet. This may either be done using an NEFM (Network Electronics Filler Module -

A network switch built into the lower slot of one of the racks) or using an external network

hub or switch.

Ethernet with a NEFM

If one of your racks is supplied with a NEFM, run a CAT5 cable from each rack to the rack

with the NEFM. You may make the connection either using prefabricated CAT5 network

cables, or using CAT5 cable and the termination kits provided.

Ethernet with an External Network

If the system has an external network, connect each rack to the external hub or switch using

CAT5 cable. A network termination kit is provided with each rack (in the door) for the

Sensor3 rack. You may need to provide termination at the network switch, e.g. a patch

panel.

Figure 23: Ethernet connections with a NEFM

Ethernet

Ethernet

Sensor3 racks

Congo

CEM3
NEFM

CEM3

Figure 24: Ethernet connections with an external network

Congo

Sensor3 racks

Ethernet

Ethernet

CEM3

CEM3

CEM3

CEM3

Advertising