Control and Data Connections

21

with the rack and should be ordered separately.

Step 2:

If needed, terminate both the outgoing cables into the third header, “PASS-

THRU”. This header is located below the primary DMX headers and has both the

DMX A and DMX B connections available as shown above.

Setting DMX Termination

After completing data connections you must properly terminate each DMX line using the

termination DIP switches on the CEM3 backplane. Data termination eliminates signal

“reflections” at the end of the network that interfere with network functions. Each DMX line

should have termination turned On at the last network connection.

Step 1:

Locate the termination DIP switches on the CEM3 backplane.

Step 2:

Using the label on the backplane to match data connections to the associated

termination DIP switches.

Step 3:

Set the termination switches to On (Up) or Off (Down) depending on the

connection status:

If the connection is jumpered to another rack or device, turn termination Off.

If the connection ends at the rack, turn termination On.

If a data connector is not used, either setting is acceptable.

N o t e :

The termination switches should not be set to the “RDM” position unless

recommended by ETC.

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

n/c

n/c

COM

Data +

Data +

Data -

Data -

ORG

W/ORG

BRN

GRN

W/GRN

BLU

W/BLU

W/BRN

COM

Data +

Data -

ORG

W/ORG

W/BRN

COM

Data +

Data -

ORG

W/ORG

W/BRN

ORG

W/ORG

BRN

GRN

W/GRN

BLU

W/BLU

W/BRN

COM

If daisy-chaining to

another rack or

DMX device...

DMX A

Thru

DMX B

Thru

From source

DMX A

From source

DMX B

Figure 22: IDC DMX Connection