Sensor3 ce rack specifications, A p p e n d i x a, Appendix a: sensor3 ce rack – ETC Sensor3 CE (ESR3) Rack User Manual

Page 42: Appendix a: sensor3 ce, Appendix a

Advertising
background image

34

Sensor3 CE Rack (ESR3) Installation Manual

A p p e n d i x A

Sensor3 CE Rack Specifications

All of the rack specifications apply to all of the ESR3 series

of racks unless otherwise noted.

General

Racks available in four sizes

ESR3-12 12 modules, 24 dimmers maximum
ESR3-24 24 modules, 48 dimmers maximum
ESR3-36 36 modules, 72 dimmers maximum
ESR3-48 48 modules, 96 dimmers maximum

Dual density (two dimmers per module) and single density

dimmer modules available

Environmental

Operating temperature: 0-40C / 32-104F
Dimmer room HVAC systems must at all times maintain the

specified ambient temperature at the dimmer rack.

Dimming systems operating within 10 degrees C of the

upper or lower temperature limits must strictly follow

installation and operation guidelines to operate reliably.
Relative humidity: 30-90% non-condensing
Altitude: Below 2000 metres.

Mechanical

Rugged 16-gauge steel construction
Fine-textured, scratch-resistant, epoxy paint
ESR3-12 uses wall mount installation
ESR3-24 can be wall or pedestal mounted
ESR3-36 and ESR3-48 are floor mounted
Top and bottom cabling access through removable panels
Screwdriver required for module removal or installation
Keyed module slots prevent insertion of inappropriate

module types
Front access to all wiring and terminations
Full height locking door
Electrostatic air filter easily removed from door for periodic

cleaning
High efficiency cooling system with airflow sensor
High visibility LED status beacon

Electrical

ESR3 racks accept:

Single phase 230V AC (3-wire)

ESR3-36: restricted to a max.600A across all circuits

ESR3-48: restricted to a max. 800A across all circuits

Three phase 230/415 V AC (3-wire)
Line feed frequencies from 47-63Hz
Maximum current ratings:

ESR3-12 – 200 amps per phase (3 phase max.)
ESR3-24 – 400 amps per phase (3 phase max.)
ESR3-36 – 600 amps per phase (3 phase max.)
ESR3-48 – 800 amps per phase (3 phase max.)

These are absolute maximum current ratings. You may use

less dependant on the type and number of dimmer

modules.
Operational Voltage (U

e

): 230V +/-10% (3p + N + E)

Insulation Voltage (U

i

): 400V

Impulse Withstand Voltage (U

imp

): 4000V

Short-circuit current: 10kA Minimum (Consult Factory)

Degree of Protection: IP20

Types of Electrical Connection: W.W.W

EMC Environment: 1
Pollution Degree: 2
Complies with Low Voltage Directive 73/23/EC
Electromagnetic Compatibility Directive 89/336/83/EC

Complies with all applicable European

Directives and associated Standards for

product safety and electromagnetic

compatibility.

Control

Sensor3 Control Electronics Module (CEM3) electronics
Redundant Tracking of dual control modules available in

ESR3-24, ESR3-36 and ESR3-48
Single Ethernet control signal input
Two DMX512 inputs
Standard diagnostic reporting

Options

Advanced Features™ dimmer-specific load and diagnostic

reporting (included with ESRAFN3 racks)
Vibration reduction kits available for all racks
SSSH Hood for noise reduction

Rack Dimensions

Empty Rack Weights

Model

Weight (kg)

ESR3-12

31

ESR3-12 Door*

5

ESR3-24

60

ESR3-24 Door*

8

ESR33-6

75

ESR3-36 Door*

11

ESR3-48

113

ESR3-48 Door*

14

* Racks ship with door unattached, but in same crate.

Installed Rack Weights*

Model

Weight (kg)

ESR3-12

66

ESR3-24

128

ESR3-36

176

ESR3-48

247

Typical - ED15 modules (2.5kg/slot)
Refer to module datasheets to calculate total rack weight for
other module types

Load Wiring Lug Capacity

Connection

Wire Size

6/10/15A, 25A and 50A lugs

16mm

2

Max.

Installation Rack Dimensions - Including Door

Model

Height (cm)

Width (cm)

Depth (cm)

ESR3-12

65

37.5

42.5

ESR3-24

124

37.5

50.5

ESR3-36

170.5

37.5

50.5

ESR3-48

217

37.5

58.1