4

Control and Data Connections

19

C h a p t e r 4

Control and Data Connections

Sensor3 racks support a variety of control and data connections on the CEM3 backplane.

CEM3 backplanes have connectors for:

Two DMX512 Cables (Universes)

External Panic Circuit Activation and Indication

Remote Redundant Tracking selection switch (Dual Backplane Only)

Ethernet Network

Station Wiring

Dual and Single Backplane Differences

To use dual control modules your rack must be fitted with a dual tracking backplane. Racks

without dual tracking may have an empty second slot, or use the second slot to hold a

network switch. The exception is ESR3-12 racks, which only have space for a single control

module.

Racks with a dual backplane also have a three position switch which allows manual

switching of control of the rack to the top CEM3, the bottom CEM3, or for automatic

switching between the two.