Installing Dimmer Modules

Step 1:

Inspect each dimmer module for loosened components or shipping damage.

Step 2:

Slide dimmer modules into the rack. If you are installing a mix of module types,

consult the included project drawings for the correct module order.

Step 3:

Push each module into its slot until it is flush with the front of the rack.

Installing Module Locking Bars

The module locking bars to the left of the rack are provided to prevent module removal

without use of a tool. It is an important requirement that they are fitted once installation is

complete.

Step 1:

Slacken off the three Phillips screws that secure each module locking bar in

place.

Step 2:

Slide the module locking bars to the right fully, so that they overlap the edge of

the dimmer modules.

Step 3:

Tighten the Phillips screws fully and check that modules cannot be removed.

Completing Installation

Once you have completed installation, please fill in

Appendix B: Sensor3 Installation

Checklist, page 35

for the system and return it to ETC. The system will then be covered

under the ETC warranty programme.

C A U T I O N :

The module locking bars should always be installed once installation is complete.

Failure to do so leaves the end user open to risk of electric shock.