Securing sensor3 racks to a wall, Figure 3, Use figure 3 – ETC Sensor3 CE (ESR3) Rack User Manual

Page 15: N o t e

Advertising
background image

2

Installation of Racks

7

Securing Sensor3 Racks to a Wall

Racks installed on the floor or a pedestal can also be secured to a wall for greater stability.

Step 1:

Prepare the rack for floor or pedestal mounting (

Installing ESR3-36 and ESR3-

48 Racks on the Floor, page 6

or

Pedestal Mounting an ESR3-24 Rack, page 6

).

Step 2:

Mark the locations for your securing hardware on the wall.

For ESR3-12 or ESR3-24 racks, use the diagram in Figure 2 to determine

where you need to install your hardware.

For ESR3-36 and ESR3-48 racks, put the rack in position and mark the holes

directly.

Step 3:

Drill holes or install mounting hardware in the marked locations.

Step 4:

Finish mounting the rack to the floor or pedestal.

Step 5:

Attach the rack to the wall with your securing hardware.

W A R N I N G :

Make sure the holes for the mounting hardware are located where the

hardware cannot come into contact with electrical wiring. Make all

modifications in accordance with your country’s electrical codes.

N o t e :

Be sure to level your racks before marking the hole positions.

ESR3-48 Floor mount hole diagram

ESR3-36 / ESR3-24 Floor mount hole

Dia. 10mm

480mm

294mm

79mm

32mm

373mm

511mm

Figure 3: Hole diagrams for mounting racks to the floor

Dia. 10mm

404mm

294mm

79mm

32mm

373mm

436mm