Sensor3 CE Rack (ESR3) Installation Manual

Converting Neutral Disconnect Slots

There are two classes of modules available for Sensor3 CE racks - modules which break

the neutral, such as RCD or ND modules, and single pole modules that do not. Normally

your rack will be configured by ETC at the factory for the correct module types, however if

you have a mixture of modules or you have not been able to supply details of slot

allocations you may need to configure some slots on site.

Step 1:

Determine which dimmer slots you will be converting. You can convert either

individual slots or a three-slot strip at a time.

Step 2:

Gently bend the neutral lug retraining tab out with a

small flat blade screwdriver until the lug releases and

you are able to pull it out. See Figure 15.

Step 3:

Use a flat blade screwdriver to loosen the threaded

inserts until the contact plates can slide out of both

lugs.

Step 4:

Repeat

Step 2

and

Step 3

for the other dimmer slot

lug.

Step 5:

Install a Neutral lug jumper into the lugs and tighten

the threaded inserts.

Step 6:

Slide the jumpers into the plastic lug strip until the lug tab clicks into place.

Step 7:

Secure the jumper to the thread on the Neutral bus bar using the provided

M3x8mm screw.

Repeat Steps 1 through 6 for any other lugs you want to convert

C A U T I O N :

Lug catches will break if bent too far. Only bend the

catch until the lug releases.

Figure 15: Removing a lug

Use a small flat screwdriver

to lift the lug tab enough to

release the lug from the strip

and pull it out.

Figure 16: Converting Neutral Disconnect lugs to use single pole dimmers