2 assignment of the i/o terminals, 1 setpoint and control signals, 9400 technology applications | table positioning – Lenze E94AxHE Technology Application Table positioning User Manual

Page 13

Advertising
background image

EDS94TA10050xxxx EN 1.2 - 03/2010

L

13

9400 Technology applications | Table positioning

Parameter setting & configuration

Assignment of the I/O terminals

5.2

Assignment of the I/O terminals

5.2.1

Setpoint and control signals

The following tables contain the Lenze assignment of the analog and digital inputs for the

"Table positioning" technology application.

Analog inputs

Digital inputs

Terminal X3

Signal (Lenze setting)

AI1-

AI1+

Selection for speed override



Speed/acceleration override ( 27)

AI2-

AI2+

Selection for acceleration override



Speed/acceleration override ( 27)

Terminal X5

Signal (Lenze setting)

DI1

Quick stop

• If DI1 is set to LOW level, the drive is decelerated to standstill within the deceleration

time set for the quick stop function independent of the setpoint selection.

• If the quick stop function is deactivated, the drive is led to the selected setpoint again via

the set acceleration time.



Quick stop ( 30)

DI2

Connection of reference switch/touch probe sensor

DI3

Connection of travel range limit switch positive/negative for basic function "

Limiter

".

( 31)

• The inputs respond to the FALSE state (fail-safe).

DI4

DI5

Reset error

• By means of a LOW-HIGH edge an existing error status can be reset if the cause of the

fault is removed.

DI6

-

DI7

-

DI8

-

A1+

A1-

A1-

A1R

A2+

A2-

GI

RFR

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

Advertising