9400 Technology applications | Table positioning

Parameter setting & configuration

Basic settings

16

L

EDS94TA10050xxxx EN 1.2 - 03/2010

5.3.2

Traversing range

By setting the traversing range the machine type/measuring system is set:

 Parameter setting: Tab Application parameters  dialog level Overview

Traversing range
Unlimited

The drive can traverse optionally in both directions without

reaching limitations.

• Positioning here generally is effected in the positioning

modes "Relative with/without TP" or "Speed with/

without TP".

• The positioning measuring system is reset to zero with

every new positioning process.

• By homing, the positioning measuring system receives a

fixed reference point (zero point), so that also the

positioning modes "Absolute with/without TP"can be

used. Then also the software limit positions for limiting

the traversing range are provided.

Limited

After reaching the position limits, the drive must travel in the

opposite direction again.

• For positioning, the home position has to be known. By

homing, the positioning measuring system receives a

fixed reference point (zero point).

• Basically, monitoring to the internally maximum usable

value range (±2

31

increments) takes place (software limit

position monitoring of the internal value range). An

overflow of the value range results in the loss of the home

position.

• Additionally parameterisable software limit positions can

be activated on the user side for limiting the travel range.

Modulo

The measuring system is repeated.

• If the cycles n set are exceeded a defined overflow occurs.

The cycle typically corresponds to a rotation or tool

distance in a rotative system.

• For positioning, the home position has to be known.

• Software limit positions are not effective.

• Absolute targets can be approached by exceeding the

measuring system limit, e.g. from 10° via 0° to 350°.

Parameter

Lenze setting

Value Unit

C02528

Traversing range

Limited

C02536

Cycle (only relevant for traversing range "Modulo")

360.0000 unit

M

M

M

Œ