11 monitfollowerror1, 12 monitfollowerror2, 9400 technology applications | table positioning – Lenze E94AxHE Technology Application Table positioning User Manual

Page 47

Advertising
background image

EDS94TA10050xxxx EN 1.2 - 03/2010

L

47

9400 Technology applications | Table positioning

Parameter setting & configuration

Parameterisable function blocks

5.14.11

MonitFollowError1

5.14.12

MonitFollowError2

C03915

String of digits

Position unit

• Read only

C03916

-2147483647

2147483647 State

• Read only

Parameter

Possible settings

Information

Is an instance of

Function

L_LdMonitFollowError



Following error monitoring ( 28)

Parameter

Possible settings

Information

C03960

-214748.3647

unit

214748.3647 Following error at the input

• Display of the input signal

dnFollowErrorIn_p in the real unit

of the machine.

C03961

String of digits

Position unit

• Read only

C03963

Following error out of tolerance

• Read only

FALSE Following error smaller than set

switching threshold

TRUE Following error larger than set

switching threshold

C03964

Following error monitoring activated

• Read only

FALSE Deactivated

TRUE Activated

Is an instance of

Function

L_LdMonitFollowError



Following error monitoring ( 28)

Parameter

Possible settings

Information

C03965

-214748.3647

unit

214748.3647 Following error at the input

• Display of the input signal

dnFollowErrorIn_p in the real unit

of the machine.

C03966

String of digits

Position unit

• Read only

C03968

Following error out of tolerance

• Read only

FALSE Following error smaller than set

switching threshold

TRUE Following error larger than set

switching threshold

C03969

Following error monitoring activated

• Read only

FALSE Deactivated

TRUE Activated

Advertising