9400 Technology applications | Table positioning

Parameter setting & configuration

Profile data management

24

L

EDS94TA10050xxxx EN 1.2 - 03/2010

5.4.4

Positioning with final speed

If a positioning process with a final speed other than zero is carried out, a velocity

changeover / overchange can be realised, i.e. a second positioning process is started

immediately once the target position is reached, and the drive does not come to a standstill

at the first target position.

[5-5]

The principle of velocity changeover / overchange

 Normally, the drive has reached the final speed when the target position is reached.
 The profile is run through which is defined via "Profile data sequence profile without

TP".

 The final speed must not exceed the maximum profile speed.

– The speed is internally limited to the profile speed.
– This is the maximum value for the final speed if the profile speed is reduced via

override. (This behaviour may add to the cases described in the note below.)

– The speed limitation is not affected by subsequent increases in the override value.

n

Target position

o

Final speed (here unequal "0")

Œ



v

pos

v

end

v [m/s]

t [s]

Note!

Positioning processes with final speeds other than zero do not permit reversing.

In this case, the positioning process is aborted and an error is issued.
In the case of positioning processes with final speeds and if S-shaped ramps are

used, a plausibility check as to whether the final speed can be reached is carried

out when the profile is started. If the final speed cannot be reached, the

positioning process is aborted and an error is issued. This is often the case if the

positioning process has been paused and is then to be continued.