3 applicationerror2, 4 followingerrorscaling, 5 hysteresisfollowingerror1 – Lenze E94AxHE Technology Application Table positioning User Manual

Page 41: 9400 technology applications | table positioning

Advertising
background image

EDS94TA10050xxxx EN 1.2 - 03/2010

L

41

9400 Technology applications | Table positioning

Parameter setting & configuration

Parameterisable function blocks

5.14.3

ApplicationError2

5.14.4

FollowingErrorScaling

5.14.5

HysteresisFollowingError1

Is an instance of

Function

L_DevApplErr

Error handling



Application error messages ( 39)

Parameter

Possible settings

Information

C05903

980

999 Module ID

• Initialisation: 998

C05904/1...8

0

65535 Error ID

• Initialisation: 8011 ... 8018

C05905/1...8

Error response

0 None
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

Is an instance of

Function

L_TbNormalize

Scaling of the following error to a parameterisable reference variable

Parameter

Possible settings

Information

C04035

-2147483647

2147483647 Reference variable

• Setting "0" is not possible.

• Initialisation: 65536

Is an instance of

Function

L_SdSetPosition

Conversion of the following error hysteresis 1 selected in the real units of the

machine via C03917 into a position in [increments].



Following error monitoring ( 28)

Parameter

Possible settings

Information

C03917

-214000.0000

unit

214000.0000 Position value

• Initialisation: 0.0000 unit

C03918

String of digits

Position unit

• Read only

C03919

-2147483647

2147483647 State

• Read only

Advertising