9400 Technology applications | Table positioning

Parameter setting & configuration

Parameterisable function blocks

46

L

EDS94TA10050xxxx EN 1.2 - 03/2010

5.14.8

L_SdSwitchPoint1

5.14.9

LimitFollowingError1

5.14.10

LimitFollowingError2

Is an instance of

Function

L_SdSwitchPoint

Position switch points (cams)

Parameter

Possible settings

Information

C04395/1...8

State of switching range 1 ... 8

• Read only

0 Switch is off
1 Switch is on

C04396

String of digits

Position unit

• Read only

C04397/1...8

-2147483648

unit

2147483648 Switch-on position switching range

1 ... 8

C04398/1...8

-2147483648

unit

2147483648 Switch-off position switching range

1 ... 8

C04399/1...8

Enable switching range 1 ... 8

0 Switching range not enabled
1 Switching range enabled

Is an instance of

Function

L_SdSetPosition

Conversion of the following error switching threshold 1 selected in the real units of

the machine via C03911 into a position in [increments].



Following error monitoring ( 28)

Parameter

Possible settings

Information

C03911

-214000.0000

unit

214000.0000 Position value

• Initialisation: 100.0000 unit

C03912

String of digits

Position unit

• Read only

C03913

-2147483647

2147483647 State

• Read only

Is an instance of

Function

L_SdSetPosition

Conversion of the following error switching threshold 2 selected in the real units of

the machine via C03914 into a position in [increments].



Following error monitoring ( 28)

Parameter

Possible settings

Information

C03914

-214000.0000

unit

214000.0000 Position value

• Initialisation: 200.0000 unit