6 "teach" function, Deceleration and s-ramp times, Teach" function – Lenze E94AxHE Technology Application Table positioning User Manual

Page 26: 9400 technology applications | table positioning

Advertising
background image

9400 Technology applications | Table positioning

Parameter setting & configuration

Profile data management

26

L

EDS94TA10050xxxx EN 1.2 - 03/2010

5.4.6

"Teach" function

The "Teach" function of the profile data management enables the teaching of positions,

speeds, accelerations and S-ramp times.
The basic function "Manual jog" serves, for instance to approach the desired position

manually and transmits it via "Teaching" to the variable table for positions.

 Parameter setting: Tab Application parameters  dialog level Overview

L_PositionerTable

Control/setpoint inputs of the function

Signal configuration

Lenze setting

Control/setpoint input

(Multiplexer parameters)

FALSE  Teach position

C03020/1

C03016  Selection of table position for position

C03029/1

Zero position  Teach position

C03125/1

FALSE  Teach speed

C03020/2

C03017  Selection of table position for speed

C03029/2

Speed setpoint  Teach speed

C03024/1

FALSE  Teach acceleration

C03020/3

C03018  Selection of table position for acceleration

C03029/3

0  Teach acceleration

C03027

FALSE  Teach S-ramp time

C03020/4

C03019  Selection of table position for S-ramp time

C03029/4

0  Teach S-ramp time

C03028

Note!

After the function block editor is enabled the "Teach" function must be

configured directly in the FB interconnection instead of via the parameters

mentioned before!