9400 Technology applications | Table positioning

Parameter setting & configuration

Basic settings

5.3

Basic settings

5.3.1

Machine parameters

Tip!
In the »Engineer« the most important machine parameters can be directly adapted

to the machine on the Application parameters tab in the topmost Overview dialog

level.

Short overview of machine parameters

The machine parameters describe e.g. the motor end of the mechanics

used.
The setting of the machine parameters in the »Engineer» is carried out on

the Application parameters tab in the dialog level Overview Machine

parameters.

Parameter

Lenze setting

Value Unit

C00173

Mains voltage

400/415 V

C00174

Undervoltage (LU) threshold

285 V

C00600

Resp. to DC bus overvoltage

Trouble

C02520

Gearbox factor numerator: Motor

1

C02521

Gearbox factor denom: Motor

1

C02527

Motor mounting direction

Motor rotating CW

C02570

Position control structure

Phase control

C02522

Gearbox factor num.: Pos. enc.

1

C02523

Gearbox factor denom.: Pos. enc.

1

C02529

Mounting direction of position encoder

Encoder rotating CW

Description of the mechanics (load, tool)
C02528

Traversing range

Limited

C02524

Feed constant

360.0000 unit

C02525

Unit

°

C02526

User-defined unit

°

C02533

Time unit

s

C00273/1

Motor moment of inertia

Motor-dependent kg cm

2

C00273/2

Load moment of inertia

0.00 kg cm

2

M