9400 Technology applications | Table positioning

Parameter setting & configuration

Profile data management

22

L

EDS94TA10050xxxx EN 1.2 - 03/2010

 If e.g. in case of a profile linkage, several profiles are to be executed with the same

speed, the corresponding profile parameters "speed" can all refer to the same table

position.

 For an easier assignment and identification of the entered values, each table position

can be optionally provided with a comment in the »Engineer«.

5.4.3

Positioning modes

Depending on the traversing range/application, you can select between different

positioning modes which are described in the below table.

Note!

For absolute positioning, the home position must be known!
• If an absolute positioning process (positioning modes 1 ... 2 and 11 ... 16) is

started although the home position is not known, an error message is

indicated.
– In this case a programming error has occurred and the program flow must

be reset.

– If the error only occurs in a sequence profile, the last valid deceleration is

used to decelerate the drive to standstill.

The modulo positioning modes may involve reversing processes!
• If a modulo positioning process (positioning modes 11 ... 16) is started at an

initial speed other than zero, the target position may be overtravelled and a

reversing process may follow, depending on the selected deceleration / S-

ramp time parameters. This would also cause e.g. counter-clockwise rotation

in the "Absolute CW (modulo)" positioning mode.

Positioning mode

1 Absolute

The axis travels to an absolute position.

• Reference for the absolute position is zero position.

• The home position must be known.

• The traversing range is limited:

–to 214748.3647 [unit]

–by the internal display area (±2

31

increments)

• Not possible with "modulo" traversing range.

2 Absolute TP

Like mode 1, but with profile change when a touch probe is detected.



Touch probe positioning

.

( 25)

5 Relative

The axis is traversed by a distance.

• Reference for the distance is the target position of the profile executed before.

• The feed per positioning is limited:

–to 214748.3647 [unit]

–by the internal display area (±2

31

increments)

6 Relative TP

Like mode 5, but with profile change on touch probe detection.



Touch probe positioning

.

( 25)