EDS94TA10050xxxx EN 1.2 - 03/2010
L
17
9400 Technology applications | Table positioning
Parameter setting & configuration
Basic settings
5.3.3
Position control
In the dialog level Overview LS_Positioner and the subordinate dialog levels, you can
adapt the parameters for the position control, if necessary.
Parameter
Lenze setting
Value Unit
C00254
Phase controller gain
20.00 1/s
C02553
Position controller gain
20.00 1/s
C02556
Position controller limitation
214748.3647 unit/s