3 position control, 9400 technology applications | table positioning – Lenze E94AxHE Technology Application Table positioning User Manual

Page 17

Advertising
background image

EDS94TA10050xxxx EN 1.2 - 03/2010

L

17

9400 Technology applications | Table positioning

Parameter setting & configuration

Basic settings

5.3.3

Position control

In the dialog level Overview LS_Positioner and the subordinate dialog levels, you can

adapt the parameters for the position control, if necessary.

Parameter

Lenze setting

Value Unit

C00254

Phase controller gain

20.00 1/s

C02553

Position controller gain

20.00 1/s

C02556

Position controller limitation

214748.3647 unit/s

Advertising