9 limiter, R basic function, Limiter – Lenze E94AxHE Technology Application Table positioning User Manual

Page 31: The in, 9400 technology applications | table positioning

Advertising
background image

EDS94TA10050xxxx EN 1.2 - 03/2010

L

31

9400 Technology applications | Table positioning

Parameter setting & configuration

Limiter

5.9

Limiter

[5-12] Basic function "Limiter" (schematic diagram)

 The software limit positions which can be set via parameters serve to limit the travel

range by means of software and prevent that travel commands are executed which

would cause an exit of the permissible travel range.

 Moreover, the travel range limits are monitored via limit switches via the digital inputs

DI3 and DI4.

 Parameter setting: Tab Application parameters  dialog level Overview Limiter

The basic function "Limiter" monitors the

travel range limits via limit switches and

parameterisable software limit positions

and after an according request from the

safety module can lead the drive into

defined limit ranges. Furthermore higher-

level limit values for travel profiles can be

entered and activated.

n

t

LS_Limiter

Status

machine

(basic drive

functions)

M

DI4

DI3

Note!

The digital inputs DI3 and DI4 are configured fail-safe in C00114/3 and C00114/

4 , i.e. a HIGH level is expected at both inputs in idle state.
• If the travel range limits should not be monitored (e.g. in case of a rotary axis),

set the limit switch inputs of the basic function "Limiter" permanently to

FALSE.

The parameterised limit values for travel profiles are not effective for the basic

functions "speed follower", "torque follower", and "position follower"!
• For the exceeding of the limit values an error response can be set.

Parameter

Lenze setting

Value Unit

Limit values
C02707

Permissible direction of rotation

Positive and negative

C02700

Software limit positions are active

Deactivated

C02701/1

Positive software limit position

0.0000 unit

C02701/2

Negative software limit position

0.0000 unit

Only for homing, positioning and manual jog
C02702

Limitations are active

Deactivated

C02703

Max. speed

3600.0000 unit/s

C02705

Max. acceleration

3600.0000 unit/s

2

C02706

Min. S-ramp time

100 ms

Advertising