9400 Technology applications | Table positioning

Parameter setting & configuration

Following error monitoring

28

L

EDS94TA10050xxxx EN 1.2 - 03/2010

5.6

Following error monitoring

[5-9]

Following error monitoring

 Parameter setting: Tab Application parameters  dialog level Overview Following

error

n

Switching threshold

o

Hysteresis

In the Lenze setting a two-stage following error monitoring is

active.
If the parameterisable switching threshold 1 is exceeded, a

warning appears. If the higher-set switching threshold 2 is

exceeded, a "warning locked" appears.

j

Œ



Parameter

Lenze setting

Value Unit

C03911

Switching threshold 1

100.0000 unit

C03914

Switching threshold 2

200.0000 unit

C03917

Hysteresis 1

0.0000 unit

C03920

Hysteresis 2

0.0000 unit

C05902/1

Error response - following error 1

Warning

C05902/2

Error response - following error 2

Warning locked

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

TRUE  Activate following error limit 1

C03058/1

TRUE  Activate following error limit 2

C03058/2