Led indications, Led indications -2 – Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual

Page 156

Advertising
background image

4-2

Troubleshooting

LED Indications

Figure 4.1 Drive Status Indicators

Table 4.A Drive Status Indicators

DRIVE

DRIVE

SYNCHLINK

ENABLE

3

2

1

4

Frame 1 Shown

#

Name

Color

State

Description

Action

DR

IV

E

Po

w

er

S

tr

uc

tu

re

PWR
(Power)

Green

Steady

Illuminates when power is applied to the drive.

No action - no faults present

STS (Status)

Green

Flashing

Drive ready, but not running & no faults are
present.

No action - no faults present

Steady

Drive running, no faults are present.

No action - no faults present

Yellow

Flashing

A type 2 (non-configurable) alarm condition
exists, drive continues to run.

A run inhibit exists. Refer to

Table 4.B

Steady

A type 1 (user configurable) alarm condition
exists, but drive continues to run.

Red

Flashing

A fault has occurred.

Refer to Table for faults.

Steady

A non-resettable fault has occurred.

Red /
Yellow

Flashing
Alternately

The drive is in flash recovery mode. The only
operation permitted is flash upgrade.

Complete Flash Upgrade

Con

trol As

se

mb

ly

Communi

cati

ons

PORT

Refer to the
Communication
Adapter User
Manual

Status of DPI port internal communications (if
present).

MOD

Status of communications module (when
installed).

NET A

Status of network (if connected).

NET B

Status of secondary network (if connected).

Contro

l

SYNCHLINK Green

Steady

• The module is configured as the time keeper
or

• The module is configured as a follower and

synchronization is complete.

Green

Flashing

The follower(s) are not configured with the time
keeper.

Red

Flashing

• The module is configured as a time master

on SynchLink and has received time
information from another time master on
SynchLink.

ENABLE

Green

On

The drive’s enable input is high.