Figure 2.1 - Mounting Requirements

Note:There must be a minimum of 12.5mm

(0.5 inches) clearance around all sides of the controller. Use

either DIN rail or mounting holes.

À

Debris Cover

Б

Б

Leave debris cover attached during controller installation to

protect from falling debris. To ensure proper controller

operation, remove cover before applying power.

DIN Mounting

À

Use the drilling template at the back of the manual for

mounting the controller.

This product complies with Electromagnetic
Compatibility (EMC) Directive 89/336/EEC, when
the following requirements for a conforming
installation are applied:
D an input line filter must be installed to reduce

conducted emissions. Refer to the accessory
list in Appendix A.

D the controller system must be mounted in a

shielded enclosure to reduce radiated
emissions. A typical NEMA or IEC metal
enclosure is adequate.

D motor cables must be in conduit, or have

shielding/armor with equivalent attenuation to
reduce radiated emissions.

D motor cable lengths are as specified in table

2.A.

D control and signal wiring must be in conduit or

have shielding with equivalent attenuation.

EMC Directive 89/336/EEC Compliance

Min. Panel Thickness (14 GA)

Mounting Base Screws

Mounting Torque

Description

.0747 in.

# 8-32

10-14 lb. in.

English

1.9 mm

m4 x 0.7

1.13 to 1.56 Nm.

Metric

Note: See Appendix A for details on controller dimensions

and weights.

Installation and Storage

Take these actions to prolong controller life and
performance:

D store within an ambient temperature range of

-40

_ to +85_C

D store within a relative humidity range of 0%

to 95%, non–condensing

D protect the cooling fan by avoiding dust or

metallic particles

D avoid storing or operating the controller

where it could be exposed to a corrosive
atmosphere

D protect from moisture and direct sunlight
D operate at an ambient temperature range of

0

_ to +50_C

To maintain proper working conditions, install
the controller on a flat, vertical and level
surface. Use mounting screws up to 4.5mm
(0.177 inches) in diameter or mount on 35mm
DIN Rail.

Important: The conformity of this controller and
filter to any standard does not guarantee that the
entire installation will conform. Many factors can
influence the total installation and only direct
measurements can verify total conformity.

A copy of the Declaration of Conformity (DOC) is
available from your local Allen–Bradley sales
office.

Advertising