Rockwell Automation 160 SER A FRN 1.XX-4.XX User Manual

Page 42

Advertising
background image

Appendix A -Specifications and Accessories

A–2

Table A.3 - Specifications For All Controller Ratings

Input/Output Ratings (All Controller Ratings)

Output Voltage (V)

Adjustable from 0V to input voltage

Output Frequency (Hz)

0 to 240 Hertz Programmable

Efficiency (%)

97.5% (Typical)

Transient Protection

Standard 2 kV (Optional 6 kV using MOV module). See accessories on page A-5.

Environmental Specifications (All Controller Ratings)

Enclosure

IP 20

Ambient Temperature

0_C to 50_C

Storage Temperature

Ć40_C to 85_C

Relative Humidity

0 to 95% (non condensing)

Vibration

1.0 G Operational - 2.5 G Non-operational

Shock

15 G Operational - 30 G Non-operational

Altitude

1,000 m (3,300 ft.) without derating

Control Inputs (All Controller Ratings)

Control Input Type

For dry contact closure input - the controller has an internal 12V power supply that provides

10-mA (typical) current flow.

Also accepts open collector/solid state input with maximum leakage current of 50 mA

Start, Stop, Forward/Reverse

Configurable inputs for 2 or 3 wire control

SW1, SW2, SW3

(Preset Speed Model only)

Configurable Inputs for control of 8 preset speeds and 2 Accel/Decel times

Approvals and Standards Compliance (All Controller Ratings)

Approvals

О

О

О

UL508C

89/336/EEC

À

CSA 22.2

ОО

ОО

ОО

О

О

О

ОО

ОО

ОО

ОО

ОО

ОО

Designed to meet these standards

IEC 146-1-1

FCC Class A

À

and B

À

VDE 0871

À

and 0875

À

Control Inputs (Analog Signal Follower only -All Controller Ratings)

External Speed Potentiometer

1K to 10K Ohms, 2 Watts Minimum

Analog Input (4 to 20mA)

Input lmpedance 250 Ohms

Analog Input (-10 to +10 V DC)

Input Impedance 100 K Ohms

Control Output (All Controller Ratings)

Programmable Output

(Form C Relay contact)

Resistive rating: 0.4A @125V AC, 0.2A @ 230 V AC, 2A @ 30V DC

Inductive rating: 0.2A @ 125V AC, 0.1A @ 230V AC, 1A @30V DC

À

With external filters.

Advertising