3–38

Regenerative Brake Operation

Programming

Parameter No.

20

Display Units

%

Parameter Type

Read/Write

Factory Default

85% AC

BASE

Min/Max Value

75/90% AC

BASE

Drive Units

100 = 4096

AC Line Undervoltage Trip Level 1 (Not Enabled)

This parameter sets a software under voltage trip point that is active when the 1336 REGEN
Converter is not enabled. The 1336 REGEN Converter is factory set to prevent it from being
enabled when the input AC line voltage is less than 85% of the AC

BASE

volts.

For 380VAC input Line Regeneration Packages, AC

BASE

volts = 380V.

For 460VAC input Line Regeneration Packages, AC

BASE

volts = 460V.

Important: The 1336 REGEN Converter cannot be enabled for the [LUV Trip 1] to be

changed.

Parameter No.

21

Display Units

%

Parameter Type

Read/Write

Factory Default

60% AC

BASE

Min/Max Value

50/70% AC

BASE

Drive Units

100 = 4096

AC Line Undervoltage Trip Level 2 (Enabled)

This parameter sets a second software under voltage trip point that is active when the 1336
REGEN Converter is enabled. The 1336 REGEN Converter is factory set to trip if the input AC
line voltage is less than 60% of the AC

BASE

volts.

For 380VAC input Line Regeneration Packages, AC

BASE

volts = 380V.

For 460VAC input Line Regeneration Packages, AC

BASE

volts = 460V.

Important: The 1336 REGEN Converter cannot be enabled for the [LUV Trip 2] to be

changed.

Parameter No.

22

Display Units

Number

Parameter Type

Read/Write

Factory Default

0.1

Min/Max Value

0.0/0.3

Drive Units

1.0 = 4096

Phase Locked Loop Error Trip Point

The phase locked loop of the 1336 REGEN Line Regeneration Package synchronizes 1336
REGEN operation with the incoming power from the utility. This parameter allows the software
trip point of [

PLLReg Err Trip]

to be adjusted to help avoid nuisance trips due to utility

distortion.

Important: The 1336 REGEN Converter cannot be enabled for a [PLLReg Err Trip] to be

changed

i p 1

r

U V T

L

5 %

2 0

8

i p 2

r

U V T

L

0 %

2 1

6

E r r T r i p

g

L L R e

P

0

2 2

1

0 .

Advertising