Commissioning Your 1394 SERCOS Interface System

1-5

Use the figure below to locate the 1394C-SJT22-D System Module
connectors and indicators.

Figure 1.2
1394 System Modules (1394C-SJT22-D)

Note: Power, feedback, and I/O connectors are shown, however for

wiring information, refer to the 1394 SERCOS Interface
Installation Manual
(publication 1394-IN002x-EN-P).

Enable0

Home0

Reg0_Com

Reg0_1

Pos_Otrav0

Neg_Otrav0

I/O_Com

Reg0_2

AXIS 0

Enable3

Home3

Reg3_Com

Reg3_1

Pos_Otrav3

Neg_Otrav3

I/O_Com

Reg3_2

AXIS 3

Enable2

Home2

Reg2_Com

Reg2_1

Pos_Otrav2

Neg_Otrav2

I/O_Com

Reg2_2

AXIS 2

Enable1

Home1

Reg1_Com

Reg1_1

Pos_Otrav1

Neg_Otrav1

I/O_Com

Reg1_2

AXIS 1

1

5

8

4

1 5

8

4

1

5

8

4

1

5

8

4

OUTPUT 0

OUTPUT 1

OUTPUT 2

OUTPUT 3

DRIVE SYSTEM OK

RELAY OUTPUTS

1

1394 Digital Servo Controller

System Module

SERCOS interface

TM

10

01

2

3

4 5 6

7

89

Status

DANGER

RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY

EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.

SERCOS System Module

01

2

3

4 5 6 7

8

9

OFF ON

1 2 3

1 2 3

Analog Outputs

Connector

Relay Outputs

Connector

Discrete Input

Connectors (4)

SERCOS Base Node

Address Switch

Network Status LED

SERCOS Baud Rate

and Optical Power Switches

SERCOS Transmit (Tx) Connector

SERCOS Receive (Rx) Connector

DPI/SCANport Connector

System Module, front view

(1394C-SJT22-D is shown)

System Module, bottom view

(1394C-SJT22-D is shown)

Single Point

Bond Bar

Axis 0 Auxiliary Feedback

Axis 1 Motor Feedback

Terminal Block for Logic Power, Input Power,
and External Shunt Connections

Tie Down Anchor

System Module

Status LED

1394 System Module

Front Cover

Axis 3 Motor Feedback

(in four axis system) or

Axis 2 Auxiliary Feedback

(in three axis system)

Axis 1 Auxiliary Feedback

Axis 0 Motor Feedback

Cable Clamp Grounding Bracket

(one clamp installed)

Axis 2 Motor Feedback
(in four axis system) or
Axis 3 Auxiliary Feedback
(in two axis system)