Changing default digital output settings, Changing default digital output settings -22 – Rockwell Automation 1394 SERCOS Interface Multi-Axis Motion Control System User Manual

Page 58

Advertising
background image

Publication 1394-IN024B-EN-P — February 2004

2-22

Troubleshooting Your 1394 SERCOS Interface System

Changing Default Digital Output Settings

Change the system module parameters listed below by using either
the HIM or DriveExplorer software. To locate the relay output
connector, refer to Figure 2.3.

1

When the axis is enabled, there is a delay (ms) (Drive On Delay) between the axis having torque commanded
(brake releasing) and the axis following reference.

2

When the axis is disabled, there is a delay (ms) (Drive Off Delay) between the axis reaching zero speed or the
stopping time (brake engaging), and torque removed).

To monitor dynamic system variables on digital outputs, use the
values shown in the table below.

Digital Output
Number:

HIM Display:

Controlling
Parameter:

Default Parameter
Number:

Default Parameter
Description:

Delay Parameter

(on/off):

Drive System OK

Output01 Source

662

617

Drive System OK

Output 0

Output02 Source

663

528

Axis 0 brake control

206

1

/207

2

Output 1

Output03 Source

664

1528

Axis 1 brake control

1206

1

/1207

2

Output 2

Output04 Source

665

2528

Axis 2 brake control

2206

1

/2207

2

Output 3

Output05 Source

666

3528

Axis 3 brake control

3206

1

/3207

2

Attribute:

Parameter Number

Axis 0 Parameter
(Threshold Setting
Parameter)

Axis 1 Parameter
(Threshold Setting
Parameter)

Axis 2 Parameter
(Threshold Setting
Parameter)

Axis 3 Parameter
(Threshold Setting
Parameter)

At Zero Speed

331
(124)

1331
(1124)

2331
(2124)

3331
(3124)

At Programmed Speed

330
(157)

1330
(1157)

2330
(2157)

3330
(3157)

Velocity Command
Above Limit

335
(38+)
(39-)

1335
(1038+)
(1039-)

2335
(2038+)
(2039-)

3335
(3038+)
(3039-)

Velocity Below Limit

332
(125)

1332
(1125)

2332
(2125)

3332
(3125)

Torque Above Limit

334
(82+)
(83-)

1334
(1082+)
(1083-)

2334
(2082+)
(2083-)

3334
(3082+)
(3083-)

Torque Above
Threshold

333
(126)

1333
(1126)

2333
(2126)

3333
(3126)

In Position

336
(57)

1336
(1057)

2336
(2057)

3336
(3057)

Advertising