Publication 1394-IN024B-EN-P — February 2004

2-16

Troubleshooting Your 1394 SERCOS Interface System

Axis Module Faults

Fault Message
RSLogix
(HIM):

Description:

Drive Fault
Action

RSLogix
Programmable
Fault Action?

No Fault Message

(condition indicated by
on-screen message)

(Ax: ATune Flt)

Auto tune procedure failed to complete successfully.

DISABLE

No

No Fault Message

(condition indicated by
on-screen message)

(Axis x Hookup

Fault)

Hookup procedure failed to complete successfully.

DISABLE

No

DriveHardFault

(Axis x Unknown)

Active when serial ring detects unknown axis module.

SHUTDOWN

No

AuxFeedbackFault

(Ax: Aux Fdbk AQB)

Auxiliary encoder has encountered an illegal state transition.

DISABLE

No

AuxFeedbackFault

(Ax: Aux Fdbk Comm)

Drive unable to communicate with auxiliary Smart feedback device.

STOP

No

AuxFeedbackFault

(Ax: Aux Fdbk Loss)

The feedback wiring is open, shorted, or missing.

DISABLE

No

AuxFeedback

NoiseFault

(Ax: Aux Fdbk Noise)

Excessive noise detected on feedback signals.

DISABLE

Yes

DriveUndervoltage

Fault

(Ax: Bus Loss)

The DC bus supply to the axis module was lost.

SHUTDOWN

No

DriveOvercurrent

Fault

(Ax: Desat)

Too much current in the axis module.

STOP

No

DriveEnableInput

Fault

(Ax: Drive Enable Flt)

Missing Drive Enable Input Signal

STOP

Yes

PositionErrorFault

(Ax: Follow Error)

Axis position error limit has been exceeded. This fault can be
configured for status only.

DISABLE

Yes

DriveOvercurrent

Fault

(Ax: I(t) Fault)

The output current is exceeding the time-current rating.

SHUTDOWN

No

SoftOvertravel

Fault

(Ax: ±Soft Ovrtrvl)

Axis position exceeded maximum software positive/negative travel
limit. This fault can be configured for status only.

STOP

Yes