Publication 1394-IN024B-EN-P — February 2004

Troubleshooting Your 1394 SERCOS Interface System

2-15

DriveHardFault

(Memory Init)

Memory hardware initialization fault detected.

SHUTDOWN

No

DriveHardFault

(NV Mem Init)

Non-volatile memory is corrupt.

SHUTDOWN

No

DriveHardFault

(Objects Init)

Non-volatile memory is corrupt.

SHUTDOWN

No

PowerPhaseLoss

Fault

(Phase Loss Flt

2

)

The three-phase input line is monitored and a fault will be issued
whenever a phase loss is detected.

SHUTDOWN/ STOP No

DriveHardFault

(SCANport Comm)

SCANport/DPI Communication Failed

STOP

No

SERCOSFault

(SERCOS Ring Flt)

SERCOS ring not active after being active and operational.

STOP

No

DriveHardFault

(SERCOS Init)

SERCOS hardware initialization fault detected.

SHUTDOWN

No

DriveHardFault

(Serial Ring Init)

Intermodule serial communication failed.

SHUTDOWN

No

SERCOSFault

(SERCOS Same Addr)

Duplicate node address detected on SERCOS ring.

STOP

No

DriveOvervoltage

Fault

(Shunt Time Out)

Shunt resistor continuous rating exceeded.

SHUTDOWN

No

DriveOvertemp

Fault

(Sys Overtemp)

The 1394 thermal sensor tripped when internal ambient temperature
exceeded rating.

SHUTDOWN

No

DriveHardFault

(Sys Mod Unknown)

Active when serial ring detects unknown system module.

SHUTDOWN

No

DriveHardFault

(Task Init)

Software initialization fault detected.

SHUTDOWN

No

DriveHardFault

(Unknown Fault)

Fault is detected but source is unknown

STOP

No

Fault Message
RSLogix
(HIM):

Description:

Drive Fault
Action

RSLogix
Programmable
Fault Action?