Publication 1394-IN024B-EN-P — February 2004

2-18

Troubleshooting Your 1394 SERCOS Interface System

Supplemental
Troubleshooting
Information

This section provides information for accessing and changing
parameters not accessible through RSLogix 5000 software.

Tools for Changing Parameters

Most parameters are accessible through RSLogix 5000 software.
Alternatives to RSLogix 5000 software for changing parameters include
the Human Interface Module (HIM) and DriveExplorer software. Refer
to the table below for catalog numbers.

1

Refer to DriveExplorer Getting Results Manual (publication 9306-GR001x-EN-E) for instructions.

Changing Parameters Using DriveExplorer

To navigate using DriveExplorer, refer to the figure below. In this
example, the I/O Interface group folder is open, the Analog Outputs
parameter is selected, and the parameter elements are displayed in the
box to the right.

Figure 2.1
DriveExplorer Example

Method:

Description:

Catalog Numbers:

Firmware Revision:

DriveExplorer

DriveExplorer Software

1

9306-4EXP02ENE

2.01 or later

Serial to SCANport Adapter

1203-SSS (Series B)

3.004 or later

HIM

(series B required)

Programmer Only

1201-HAP

N/A

Analog Speed Potentiometer

1201-HA1

N/A

Digital Up-Down Speed Control

1201-HA2

N/A