Publication 1394-IN024B-EN-P — February 2004

A-16

Interconnect Diagrams

The example below also shows 1394 series C axis modules with
internal brake filtering. Each axis is connected to a motor with a brake
rated at greater than 1A. A separate pilot relay is required for brake
current handling.

Note: Suppression devices and pilot relays impact motor brake

response time.

Figure A.14
Isolated Brake (with pilot relay) Interconnect Diagram

Note: Refer to Figure 1.3 for the location of the TB1/TB2 connectors

and pin-out diagram.

Note: Refer to figures 1.1 and 1.2 for the location of the 10-pin relay

output connector.

Motor Series:

Brake Option:

Brake Response Time
Pickup/Dropout
mSec

1326AB-B5

K5

150/25

1326AB-B7

K7

120/30

1326AS-B6

K6

114/11

1326AS-B8

K8

200/12

MPL-B5 (460V)

4

70/50

MPL-B6 (460V)

4

200/120

MPL-B8 (460V)

4

250/200

MPL-B9 (460V)

4

300/200

24V DC

Power Supply

+ DC

DC com

CR6

10

9

Relay

Output 0

CR7

8

7

Relay

Output 1

CR8

6

5

Relay

Output 2

CR9

4

3

Relay

Output 3

1394 SERCOS Interface Control Board 1394C-SJT

xx-D

CR9

CR8

CR7

CR6

TB1

TB2

Axis 0

Axis 1

Axis 2

Axis 3

TB1

TB2

TB1

TB2

TB1

TB2

I >1A

I >1A

I >1A

I >1A

1 2

3 4

Motor Brake

1 2 3 4

1 2 3 4

1 2

3 4

1 2 3 4

1 2

3 4

1 2 3 4

1 2

3 4

1394C-AM

xx

Motor brake
filter (Series C)

Brake current rated

greater than 1.0A

1394C-AM

xx

Motor brake
filter (Series C)

Brake current rated

greater than 1.0A

1394C-AM

xx

Motor brake
filter (Series C)

Brake current rated

greater than 1.0A

1394C-AM

xx

Motor brake
filter (Series C)

Brake current rated

greater than 1.0A

1 2

1 2

1 2

1 2