Rockwell Automation 6189V-xxxx Non-display Industrial Computers User Manual User Manual

Page 25

Advertising
background image

Rockwell Automation Publication 6177R-UM002D-EN-P - October 2014

25

Installation

Chapter 2

4. See

Figure 9

to decide which mounting holes to use on the bracket.

5. Drill holes in the wall or shelf to accommodate screws sized M6…M8.

Figure 9 - Mounting Hole Locations on 750R Computers

6. Fasten the computer to the wall or shelf with M6…M8 mounting screws.

Callout

Dim, mm (in.) Qty

Description

A

Ø 10 (0.39)

4

Use these mounting holes for the following.
You are replacing a legacy computer.
Shock and vibration are not environmental elements.

B

Ø 6.5 (0.25)

8

Use these mounting holes when shock and vibration are environmental
elements.

Bottom Mounting Bracket Hole Locations

Dimensions are in mm (in.).
IMPORTANT: Bottom view is enlarged
for detail and not in scale to front view.

120 (4.73)

120 (4.73)

120 (4.73)

24 (0.95) x 4

382.1 (15.04)

60 (2.36)

240 (9.45)

210

(8.27)

194

(7.64)

70.5 (2.78)

375

(14.76)

360

(14.17)

A

B

Side Mounting Bracket Hole Locations

120 (4.73)

120 (4.73)

120 (4.73)

382.1 (15.04)

60 (2.36)

240 (9.45)

401.6

(15.81)

385.6

(15.18)

70.5 (2.78)

185 (7.28)

175 (6.89)

Mounting Hole Details (all brackets)