Chapter 5

UEFI Set-up Utility

Table 2 - Serial Port 1 Configuration

Table 3 - Serial Port 2 Configuration

Table 4 - Parallel Port Configuration

Parameter

Description

Serial Port 1

Enables or disables the serial (COM1) port.
Options: Enabled (default) or Disabled

Device Settings

Displays the Base I/O address and IRQ setting of serial port 1.

Change Settings

Select an optimal setting for the super I/O device.
Options: Auto (default), I/O=3F8h; IRQ=4, I/O=2F8h; IRQ=4, I/O=3E8h; IRQ=4,
I/O=2E8h; IRQ=4

Parameter

Description

Serial Port 2

Enables or disables the serial (COM2) port.
Options: Enabled (default) or Disabled

Device Settings

Displays the Base I/O address and IRQ setting of serial port 2.

Change Settings

Select an optimal setting for the super I/O device.
Options: Auto (default), I/O=2F8h; IRQ=3, I/O=3F8h; IRQ=3, I/O=3E8h; IRQ=3,
I/O=2E8h; IRQ=3

Parameter

Description

Parallel Port

Enable or disables the parallel (LPT/LPTE) port.
Options: Enabled (default) or Disabled

Device Settings

Displays the Base I/O address and IRQ setting of the parallel port.

Change Settings

Select an optimal setting for the super I/O device.
Options: Auto (default), I/O=378h; IRQ=5, I/O=278h; IRQ=5, I/O=3BCh; IRQ=5

Device Mode

Select a printer mode.
Options: Standard Parallel Port Mode (default), EPP Mode, ECP Mode, EPP Mode,
and ECP Mode