I/o data parameters – Rockwell Automation 1440-VLF02-01RA XM-121 Absolute Shaft Module User Manual

Page 76

Advertising
background image

Publication GMSI10-UM014D-EN-P - May 2010

68 Configuration Parameters

I/O Data Parameters

The I/O data parameters are used to configure the content and size of the
DeviceNet I/O Poll response message.

Status

Shows the status of the trend data.

Possible status values:

Not collected - No trend data is
currently collected.

Collecting - A trigger has occurred
and data is being collected.

Collected - A trend has been saved
to the buffer and is available to view
and upload.

View Trend Data

Displays a plot of the collected trend data.

Reset Trigger

Resets the trigger if Latch enabled is selected. This
allows the module to overwrite the previous trend
data when the machine speed crosses into the speed
range.

SU/CD Trend Parameters

Parameter Name

Description

Values/Comments

IMPORTANT

The Absolute Shaft module must be free of Poll
connections when configuring the Poll Output (Poll
Response Assembly)
and Poll Size. Any attempt to
download the parameters while a master device has
established the Poll connection with the XM module will
result in an error.

To close an existing Poll connection with an XM-440,
switch the XM-440 from Run mode to Program mode.
Refer to Changing Operation Modes on page 81.

To close an existing Poll connection with other master
devices, remove the module from the scan list or turn off
the master device.

I/O Data Parameters

Parameter Name

Description

Values/Comments

COS Size (XM Serial
Configuration Utility only)

The size (number of bytes) of the Change of State
(COS) message.

The COS Size cannot be changed.

COS Output (XM Serial
Configuration Utility only)

The Assembly instance used for the COS message.
The COS message is used to produce the Alarm and
Relay status for the module.

The COS Output cannot be changed.
Refer to COS Message Format on
page 86 for m
ore information.