74 Specifications

Inputs

Channel 1

Channel 2

Transducer Power

Voltage Range

Sensitivity

Input Impedance

Eddy current transducer
Supports 5, 8, & 11 mm Allen-Bradley 2100
Series and Bently Nevada 3300 XL Series
probes

Case Mounted Sensor
Supports the following sensors:
9000A Gen. Purpose Accel
9100VO Vel Output Accel
9100 CSA Gen Purpose Accel
9100T High Temp Accel

Constant voltage (-24V dc)*
Constant current (4.5 mA ±20% from 24 V
supply)
None (voltage input)

*Tachometer may be powered, constant
voltage, or configured as voltage input.

Selectable in software as 0 to ±20 V (min)
40 V max. peak-to-peak

User configurable in software

Greater than 100 k

Tachometer

1 Tachometer Input

Input Impedance

Speed/Frequency Range

Speed Measurement Error

Pulses per Revolution

Max Rate of Change of Speed

±25 V (50 V max. peak to peak)
1 to 50,000 events per revolution

120 k minimum

1 to 1,200,000 RPM
0.0167 to 20,000 Hz

1 to 120 RPM ± 0.2 RPM
121 to 600 RPM ± 1 RPM
601 to 4000 RPM ± 2 RPM
4001 to 24,000 RPM ± 10 RPM
24,001 to 120,000 RPM ± 20 RPM
120,001 to 600,000 RPM ± 80 RPM
600,001 to 1,200,000 RPM ± 160 RPM

0 (tach disabled) to 50,000

500 Hz/sec

XM-121 Absolute Shaft Technical Specifications

Product Feature

Specification