Load Current Monitoring and Diagnostics Installation and Operation Handbook

D-2 2408 and 2404 Controller

1.

EXAMPLE WIRING DIAGRAM (FOR MODE 1 & 2 OPERATION)

Hardware Required

1. SSR type TE10/PDS2 OR
2.
Intelligent current transformer type PD/CTX + contactor or zero voltage switching SSR
2408 or 2404 controller configured for PDS mode 2 option using logic output. This module
must be fitted in module position 1. (order code M2).




















Figure D.1 Connections for Mode 1 & 2

WARNING!

Take care that the controller is correctly wired for the mode of operation which is
configured. Failure to do so may be hazardous in some situations.

Heater

Heater

power fuse

(load

dependent)

L N

Controller
Fuse 2A(T)

N

L

V+

V-

1B

1A

M

O

D

U

L

E

1

C

O

M

M

S

1

+

-

+

PV

-

C

O

M

M

S

2

Alternative current regulator

arrangements:-

The TE10/PDS2 contains integral power

regulator and intelligent PDCTX

The PDCTX can be supplied separately for

use with any SSR or logic thyristor unit as

shown in the diagram below.

The output drive capability of the PDCTX is

5V at 7mA maximum

PDCTX
Intelligent
Current
Transformer

Logic input

SSR

+

+

-

-

To

Heater

To L

To logic output
1A & 1B

TE10
Solid
State
Relay

T/C

+

-

L N

This
represents
a single
turn
through the
CT