Prog, Hb v, List – Thermcraft XST-3-0-36-3V User Manual

Page 226: Band

Advertising
background image

Programmer Operation

Installation and Operation Handbook

5-10

2416 Controller

CREATING A NEW PROGRAM OR MODIFYING AN EXISTING ONE

The only difference between creating a new program and modifying an existing one, is that a
new program starts with all its segments set to ‘

End’ in the ‘tYPE’ parameter. The procedure

for both consists of setting up the parameters in the ‘

ProG’ list of the Operation Navigation

Diagram shown in Chapter 2. As explained earlier, under ‘Programmer States’, temporary
changes can be made to these parameters while in the HOLD state, but permanent changes (to
the stored values) can only be made when the programmer is in the Reset state. So, before
modifying a stored program first make sure that it is in Reset and then follow the procedure
below:

Program edit list

From the Home display press

until you reach the ‘

ProG

LiSt’ header.

Press

Program number
This display only appears on the four-program controllers.
Use

or

to select the number of the program which you

wish to modify (from 1 to 4).

Press

Holdback type
[Only appears when Holdback has been selected for the whole
program.]
Use

or

to select:

OFF

Holdback disabled

Lo

Deviation Low Holdback

Hi

Deviation High Holdback.

bAnd

Deviation Band Holdback

Press

Holdback value
Use

or

to set a value.

Press

(Continued on the next page.)

prog

List

prog

1

Hb

band

Hb V

5.0

Advertising
This manual is related to the following products: