Installing the wall receptacle – Dynojet 250ix: Pit Installation Guide User Manual

Page 131

Advertising
background image

P O W E R R E Q U I R E M E N T S A N D I N S T A L L A T I O N

Locations Using 60 Hz Power (North America and Japan)

Version 3

In Ground Model 200iPX/250iPX Motorcycle Dynamometer Installation Guide

B-3

I

NSTALLING

THE

W

ALL

R

ECEPTACLE

The wall receptacle is included with your dyno and is shipped in a box in the center of
your dyno or may be shipped in advance in a separate package.
The wall receptacle is a single phase 240 volt 30A dedicated circuit with a neutral
connection and a ground. The neutral connection is required to split the 240 volt into
two 120 volt connections internal to the dyno.
The cable carrying the power to this receptacle should be ten gauge or larger. Check
with local building codes for the correct size.
1

Connect one of the 240V legs (line 1) to the X terminal (gold colored screw).

2

Connect the other 240V leg (line 2) to the Y terminal (gold colored screw).

3

Connect the neutral conductor to the W or WH terminal (silver screw).

4

Connect the ground conductor to the green grounding screw.

Advertising
This manual is related to the following products: