Dynojet 250ix: Pit Installation Guide User Manual

Page 61

Advertising
background image

I N S T A L L A T I O N

Routing Cables

Version 3

In Ground Model 200iPX/250iPX Motorcycle Dynamometer Installation Guide

2-39

R

OUTING

THE

E

DDY

C

URRENT

B

RAKE

, B

ATTERY

,

AND

D

YNO

P

OWER

C

ABLES

1

Route the eddy current brake cable (P/N 66952005) from the eddy current brake
through the designated power pit conduit and to the theta controller.

2

Route the battery cable (P/N 76950312) from the CPI through the same conduit
and over to the battery. Refer to the steps and Figure 2-32 on page 2-40 for
instructions on connecting the battery and starter cables.
Note: Be sure to keep the power and communications cables in different pit
conduits.

3

Route the temperature sensor cable from the eddy current brake through the
designated pit conduit and to the Breakout board, see Figure 2-35.

4

Route the dyno power cable from the CPI to your power source, but do not plug
it in yet.

Figure 2-31: Route the Eddy Current Brake, Battery, and Power Cables

PD207

battery cable

dyno power cable

CPI

eddy current

brake cable

battery

dyno

electronics

route power cables

in designated conduit

starter

theta

controller

temperature
sensor cable

starter cable

Advertising
This manual is related to the following products: