Steel reinforcing, Step 2) step 3) – EFCO 403 Series Storefront User Manual

Page 49

Advertising
background image

EFCO CORPORATION 1/2013 PART NO. Y001

Page 49 of 94

Series 401,402, & 403 Installation Instructions

w/ L101 STEEL

9209

w/ L100 STEEL

(ALUMINUM EQUIVALENT)

COMBINED IXX = 6.870

SCREW APPLIED
TRANSOM GLAZING

COMBINED IXX = 10.059

(ALUMINUM EQUIVALENT)

9212 / 9221

w/ L102 STEEL

w/ L101 STEEL

9309 / 9311

w/ L100 STEEL

9102

Fig. # 25

(ALUMINUM EQUIVALENT)

(ALUMINUM EQUIVALENT)

(ALUMINUM EQUIVALENT)

COMBINED IXX = 6.890

COMBINED IXX = 6.586

COMBINED IXX = 6.365

L-100 FOR TUBULAR MULLIONS
L-101 FOR EXPANSION MULLIONS

STEP 2)

STEP 3)

Cut the steel reinforcing to mullion length minus 3" and set flush
with the bottom of the vertical. Paint cut ends to prevent rust.
Insert the steel into the mullion, then drill through the deep pocket
of the mullion and the steel at 16" O.C. - maximum spacing.

Tap the holes in the steel to accept # 12-24 machine screws.

SECTION III: E. STEEL REINFORCING

DRILL AND CLEAR HOLE FOR

OR AS SPECIFIED ON SHOP DRAWING.

# 12-24 X 3/8" F.H.M.S. AT 16" O.C.

STEP 1)

9103 / 9104

Drill a clear hole in the mullion with a Ø.221 (#2) drill bit. Install

the steel with M109 screws (#12-24X3/8" F.H.M.S.).

NOTE: The flat head does not countersink into the mullion.






























































Advertising
This manual is related to the following products: