Series 401,402, & 403 Installation Instructions






























































These recommendations are for general erection procedures only. For

actual job conditions, see the details on the shop drawings. For perimeter
anchor type and spacing, refer to the approved shop drawings or consult
the project design professional

.

ALSO SEE THE DOOR INSTALLATION INSTRUCTIONS #Y015.

the back of the threshold and sides of

EXTERIOR

Fig. # 56

Fig. # 55

At the option of the erector,

Fig. # 53

located at the fasteners.

Attach through the header

with flat head screws

Fig. # 52

SECTION IV: A. DOOR FRAME INSTALLATION

located 6" from the ends and

use the perimeter adaptor
continuously or 3" long pieces

INTERIOR

at jambs.

Attach through the threshold
with flat head screws.

Continuous bead of sealant at

When the jamb members are plumb and
anchored, snap-in the door stop.

Anchor through the glazing pocket

24" on center, maximum spacing.

the jambs and tied into mullion sealant

Door jamb set in sealant.

at the condition.

Transom bar shown,
jamb anchoring using

fin stop jamb
is similar.

as shown, from jamb to jamb

Seal the interior glass stop

at the transom bar.

Fig. # 54

TYP. TRANSOM

GLASS STOP

9126

Do not seal the
exterior glass stop,
this will allow weepage.