Sill flashing installation, Fig. # 58, Fig. # 57 – EFCO 403 Series Storefront User Manual

Page 61: Fig. # 59

Advertising
background image

EFCO CORPORATION 1/2013 PART NO. Y001

Page 61 of 94

Series 401,402, & 403 Installation Instructions






























































These recommendations are for general erection procedures only. For

actual job conditions, see the details on the shop drawings. For perimeter
anchor type and spacing, refer to the approved shop drawings or consult
the project design professional

.

DOOR

and married into the bead of sealant that the sill flashing is set into.

Make sure the bead of sealant under the threshold is continuous through the door jamb

when using thermal flashing.

Apply a continuous bead of sealant

across the top of the thermal strut

NOTE:

Fig. # 58

UNIT

1G65 - STANDARD

1G64 - w/ F098 CLIP

1G85 - w/ STOOL TRIMS

{

Fill the vertical glazing pocket with sealant to

divert any water onto the flashing.

Continuous bead of sealant

Before the fastener is inserted,

See figures below.

SECTION IV: B. SILL FLASHING INSTALLATION

Install the sill flashing continuously between the masonry jambs
or between the door frame and the masonry jamb.

Fig. # 57

Sealant

STEP 1)

THERMAL

{

1G65 - STANDARD
1G85 - w/ STOOLS

Shim the flashing if required until

it is level and set it in a continuous

Seal the ends of the flashing with a

bead of sealant.

"skinning", nonhardening type of
sealant (i.e., silicone).

Sealant

9947 - LITE
9957 - STD.

1G64 - w/ CLIP

Optional sill flashings:

Fig. # 59

force sealant into the hole for the

flashing fastener to ensure that the
hole through the flashing is sealed.
Seal over the heads of all sill attachment
screws with sealant.

ALL THERMAL STRUT SILL FLASHING THAT WOULD

ENCOUNTER MOISTURE MIGRATION MUST HAVE THE

THERMAL STRUT SEALED OVER WITH SILICONE.