High side lite base installation, Fig. # 77, Fig. # 76 – EFCO 403 Series Storefront User Manual

Page 71

Advertising
background image

EFCO CORPORATION 1/2013 PART NO. Y001

Page 71 of 94

Series 401,402, & 403 Installation Instructions

( for interior use only w/o sill flashing )

in a continuous bead of sealant that will run vertical to vertical. When a

CONTINUOUS w/o SILL FLASHING -

adaptor (#9149) can be utilized. Locate the base adaptor pieces 6" from

sill flashing is being incorporated, the use of 4" long pieces of the base

the verticals and 24" on center, with a minimum of 3 per DLO.

4" LONG PIECE w/ SILL FLASHING

Fill and tool sealant

onto the flashing.

into the pocket
to divert water

Side lite base adaptor

# 9149

Fig. # 77 below.

SYSTEM SILL FLASHING

screws with sealant

Cover the heads of all attachment

Horizontal shear block

sealant bead

Continuous

CE

NT

ER

LIN

E

# K172/1G80

# K173/9248

# K122/9148

Set in sealant.

Fig. # 77

Cut the sill flashing to the day lite opening of the module and then set it

bead under the side lite sill flashing.

TO NEXT VERTICAL MULLION

REFER TO SECTION III F FOR SIDE LITE BASE PREP.

pocket to the next vertical.

floor at the inside line of the glazing

continuous bead of sealant on the

Start at the door jamb and run a

SECTION IV: D.

SEALANT BEAD CONTINUES

Be sure to tie the sealant bead from under
the threshold and under the jamb member
through the glazing pocket to the sealant

STEP 2)

NOTE:

STEP 1)

HIGH SIDE LITE BASE
INSTALLATION

Shear block &

Fig. # 76

screws

# K122/9148

# K173/9248
# K172/1G80

DOOR JAMB

Set in sealant.






























































Advertising
This manual is related to the following products: