Configuration Using Web-Manager


MatchPort b/g™ User Guide

31

Figure 4-9. UDP Connection Settings

Datagram Mode

Datagram Type

Configures the remote IP or network broadcast address and
the remote port. Enter 01 for directed or broadcast UDP.

Accept Incoming

Select Yes to accept incoming UDP datagrams. Other options
are No and With Active Mdm Ctrl In.

Endpoint Configuration

Local Port

Enter the local port number.

Remote Port

Enter the port number of the remote device.

Remote Host

Enter the IP address of the remote device.

Use Broadcast

Select to broadcast the UDP datagram. Datagrams of type 01
can be sent as a broadcast by enabling this option. The
default is not to broadcast.

Note:

Datagrams are sent as subnet-directed broadcasts.

Device Address Table

This table is enabled when Datagram Type is set to FD. Enter
values in the range 1-255 to identify units on the local network
of device servers.

Note:

Lantronix Tech Support supports Datagram type 01.

Datagram type FD is for OEM use.